Brocade Multi-Service IronWare Switching Configuration Gui Uživatelský manuál Strana 256

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 984
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 255
226 Multi-Service IronWare Switching Configuration Guide
53-1003036-02
Show VLAN commands
8
Defining CVLANs inside the ESI
To define CVLANs inside the ESI, enter a command such as the following.
Brocade(config-esi-acme)# vlan 10
Configuring the CVLAN to be tagged
To configure CVLAN 10 to be tagged on port 1/1, enter a command such as the following.
Brocade(config-esi-acme-vlan-10)# tagged ethernet 1/1
Show VLAN commands
The following show commands will display custom ESI configurations for VLANs.
show all vlans
To display all VLANs, enter the show all vlans command under the ESI configuration level.
Brocade(config-esi-acme)#show vlan
PORT-VLAN 10, Name [None], Priority Level -, Priority Force 0
L2 protocols : NONE
ESI: acme Encapsulation: cvlan
Syntax: show vlan
Displaying information for a VLAN inside an ESI
To display a VLAN inside an ESI, enter a command such as the following.
Brocade(config)#show esi acme vlan 10
ESI Name Encap Number of Provider Provider Provider Client
Members ESI Encap VLAN ESIs
-------- ----- --------- -------- ----- -------- ------
VLAN 10 details:
----------------
PORT-VLAN 10, Name [None], Priority Level-,Priority Force 0
L2 protocols : NONE
ESI: bay Encapsulation: cvlan
----------------
No ports associated with VLAN
Arp Inspection: 0
DHCP Snooping: 0
L2 protocol forwarding mode:Tunnel
Flood domain ID 4176
Syntax: show vlan num
Displaying information for a VLAN inside an ESI in brief format
The show vlan brief command displays VLANs in a tabular format for compactness. This command
may be executed from any CLI level.
Zobrazit stránku 255
1 2 ... 251 252 253 254 255 256 257 258 259 260 261 ... 983 984

Komentáře k této Příručce

Žádné komentáře