938 Multi-Service IronWare Switching Configuration Guide
53-1003036-02
show bfd application
25
show bfd application
The command is extended to include MPLS.
Syntax show bfd application
Parameters None.
Command
modes
This command operates in all modes.
Usage guidelines Use to display MPLS in the output.
Command
output
The show bfd application command displays the following information.
Example
Brocade# show bfd application
Registered Protocols Count: 3
Protocol VRFID Parameter HoldoverInterval
isis 0 0 2
ospf6 0 1 10
ospf 0 0 5
History
Related
commands
None.
Output field Description
Protocol Which protocols are registered to use BFD on the device.
VRFID The VRFID of the protocol.
Parameter The parameter value passed by the protocol during registration with BFD.
HoldoverInterval The time by which the BFD session DOWN notification is delayed. If within
that holdover time, the BFD session is UP then it is not notified of the BFD
session flap.
Release Command history
Multi-Service NetIron Release 05.6.00 The command is extended to include MPLS.