Multi-Service IronWare Switching Configuration Guide 929
53-1003036-02
Configuring BFD for the specified protocol
25
Displaying BFD applications
The following example illustrates the output from the show bfd applications command.
Brocade# show bfd applications
Registered Protocols Count: 3
Protocol VRFID Parameter HoldoverInterval
isis 0 0 2
ospf6 0 1 10
ospf 0 0 5
Displaying BFD for BGP neighbor information
The following example illustrates the output from the show bfd neighbor /jointfilesconvert/1441116/bgp detail command for
the MLX series and XMR series devices.
Brocade# show bfd neighbor /jointfilesconvert/1441116/bgp detail
Total Entries:4 R:RxRemote(Y:Yes/N:No)H:Hop(S:Single/M:Multi)
NeighborAddress State Interface Holddown Interval R/H
10.101.101.100 UP ve 3 3000000 1000000 Y/M
Registered Protocols(Protocol/VRFID): /jointfilesconvert/1441116/bgp/0
Local: Disc: 26, Diag: 0, Demand: 0 Poll: 0
MinTxInterval: 1000000, MinRxInterval: 1000000, Multiplier: 3
Remote: Disc: 7, Diag: 0, Demand: 0 Poll: 0
MinTxInterval: 1000000, MinRxInterval: 1000000, Multiplier: 3
Stats: RX: 14682 TX: 12364 SessionUpCount: 1 at SysUpTime: 0:2:46:24.725
Sessions The number of Transmit (Tx) and Receive (Rx) BFD sessions currently
operating on the specified interface module.
BFD Enabled ports count The number of ports that have been enabled for BFD.
Port The port on which BFD is enabled.
MinTx The interval in milliseconds during which the device sends a BFD
message from this port to its peer.
MinRx The interval in milliseconds during which this device can receive a BFD
message from its peer on this port.
Mult The number of times the device will wait for the MinRx time on this port
before it determines that the peer device is non-operational.
Sessions The number of BFD sessions originating on this port.
TABLE 128 Display of BFD applications information
This field... Displays...
Protocol Which protocols are registered to use BFD on the device.
VRFID The VRFID of the protocol.
Parameter The parameter value passed by the protocol during registration with BFD.
Holdover Interval The time by which the BFD session DOWN notification is delayed. If within that
holdover time, the BFD session is UP then it is not notified of the BFD session
flap.
TABLE 127 Display of BFD information (Continued)
This field... Displays...