FIGURE 7 WLAN Security - WEP 64 screen
5. Configure the following WEP 64 settings:
Default WEP 64 keys are as follows:
Key 1 1011121314
Key 2 2021222324
Key 3 3031323334
Key 4 4041424344
6. Select OK when completed to update the WLAN’s WEP 64 encryption configuration. Select
Reset to revert the screen back to its last saved configuration.
WEP 64 Deployment Considerations
Before defining a WEP 64 supported configuration on a WLAN, refer to the following deployment
guideline to ensure the configuration is optimally effective:
Generate Keys
Specify a 4 to 32 character pass key and select the Generate button. The pass key can be any
alphanumeric string. The wireless controller, other proprietary routers, and Brocade clients use the
algorithm to convert an ASCII string to the same hexadecimal number. Clients without Brocade
adapters need to use WEP keys manually configured as hexadecimal numbers.
Keys 1-4
Use the Key #1-4 fields to specify key numbers. For WEP 64 (40-bit key), the keys are 10
hexadecimal characters in length. Select one of these keys for default activation by selecting its
radio button. Select Show to display the actual characters comprising the key.
Restore Default WEP Keys
Select this radio button to restore the WEP algorithm back to its default settings.