Brocade Network OS Message Reference v4.1.1 Uživatelský manuál Strana 107

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 478
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 106
Network OS Message Reference 91
53-1003227-01
AUTH-1029
8
Recommended
Action
Reinitialize authentication using the shutdown and no shutdown commands or the chassis disable
and chassis enable commands.
If the message persists, execute the copy support command and contact your switch service provider.
AUTH-1029
Message Failed to get <data type> for <message phase> message: port <port number>, retval
<error code>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the authentication process failed to get a particular authentication value at certain phase.
Usually this problem is transient. The authentication may fail.
The data type is a payload or structure that failed to get memory.
Recommended
Action
Reinitialize authentication using the shutdown and no shutdown commands or the chassis disable
and chassis enable commands.
If the message persists, execute the copy support command and contact your switch service provider.
AUTH-1030
Message Invalid message code for <message phase> message: port <port number>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the receiving payload does not have a valid message code during the specified
authentication phase. Usually this problem is transient. The authentication may fail.
Recommended
Action
Reinitialize authentication using the shutdown and no shutdown commands or the chassis disable
and chassis enable commands.
If the message persists, execute the copy support command and contact your switch service provider.
AUTH-1031
Message Failed to retrieve secret value: port <port number>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the secret value was not set properly for the authenticated entity.
Recommended
Action
Reset the secret value using the fcsp auth-secret command.
Reinitialize authentication using the shutdown and no shutdown commands or the chassis disable
and chassis enable commands.