
Network OS Message Reference 107
53-1003227-01
BL-1016
8
BL-1016
Message Interface module port <port number> in <slot string> failed to enable.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the specified interface module port could not be enabled.
Recommended
Action
Make sure that the interface module is seated correctly. If the interface module is seated correctly, reload
or power cycle the interface module using the power-off and power-on commands.
Execute the diag systemverification command to verify that the interface module does not have
hardware problems.
Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.
If the message persists, replace the interface module.
BL-1017
Message <slot string> Initializing.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified slot has started initializing the ports.
Recommended
Action
No action is required.
BL-1018
Message <slot string> Initialization completed.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified slot has completed initializing the ports.
Recommended
Action
No action is required.
Komentáře k této Příručce