Brocade Network OS Message Reference v4.1.1 Uživatelský manuál Strana 436

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 478
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 435
420 Network OS Message Reference
53-1003227-01
SULB-1112
8
SULB-1112
Message Logical chassis firmware download has completed installation on rbridge-id
<rbridge IDs>.
Message Type LOG | VCS
Severity WARNING
Probable Cause Indicates that firmware upgrade has completed successfully.
Recommended
Action
No action is required.
SULB-1113
Message Logical chassis firmware download will be aborted due to failover on rbridge-id
<rbridge IDs>.
Message Type LOG | VCS
Severity WARNING
Probable Cause Indicates that firmware upgrade failed.
Recommended
Action
Execute the firmware recover or firmware activate command.
SULB-1114
Message Firmware installation has completed successfully on rbridge-id <rbridge IDs>.
Please run 'firmware activate' for firmware activation.
Message Type LOG | VCS
Severity INFO
Probable Cause Indicates that firmware upgrade has completed.
Recommended
Action
Execute the firmware activate command to activate the firmware.
Zobrazit stránku 435
1 2 ... 431 432 433 434 435 436 437 438 439 440 441 ... 477 478

Komentáře k této Příručce

Žádné komentáře