Network OS Message Reference 111
53-1003227-01
BL-1029
8
BL-1029
Message All ports on the switch will be reset as part of the firmware upgrade.
Message Type LOG
Severity INFO
Probable Cause Indicates that a recent firmware upgrade caused the switch internal processor firmware to be upgraded
and resulted in a cold upgrade. As part of the upgrade, all data path elements were reset.
Recommended
Action
No action is required.
BL-1031
Message Link timeout in internal port (slot <slot number>, port <port number>) caused
interface module fault. Use power-off/power-on commands to recover it.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that link timeout occurred in one of the back-end internal ports.
Recommended
Action
Power cycle the interface module using the power-off and power-on commands.
BL-1032
Message (<slot string>,bitmap 0x<object control flags(bitmap)>) ports never came up ONLINE
(reason <reason for port disable>, state <status of the interface module>).
Disabling slot.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that the back-end (non-user) ports have not come online within the time limit.
Recommended
Action
Reload or power cycle the interface module using the power-off and power-on commands.
Execute the diag systemverification command to verify that the interface module does not have
hardware problems.
Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.
If the message persists, replace the interface module.