Message FSS out of memory (<memory allocation with number of bytes>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the system ran out of memory.
Recommended
Action
Check memory usage on the switch using the show process memory command.
Execute the copy support command and contact your switch service provider.
FSS-1005
Message FSS read failure.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the read system call to the fabric synchronization service (FSS) device has failed.
Recommended
Action
If the message persists, execute the copy support command and contact your switch service provider.
FSS-1006
Message No FSS message available.
Message Type LOG
Severity WARNING
Probable Cause Indicates that data is not available on the fabric synchronization service (FSS) device.
Recommended
Action
If the message persists, execute the copy support command and contact your switch service provider.