Message Switch status change contributing factor Power supply: <Number Bad> bad.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty power
supplies is greater than or equal to the policy set by the system-monitor command.
Recommended
Action
Replace the faulty power supplies.
FW-1428
Message Switch status change contributing factor Power supply: <Number Missing> absent.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of missing power
supplies is greater than or equal to the policy set by the system-monitor command.
Recommended
Action
Replace the missing power supplies.
FW-1429
Message Switch status change contributing factor: Power supplies are not redundant.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the power supplies are not in the
correct slots for redundancy.
Recommended
Action
Rearrange the power supplies so that one is in an odd slot and another in an even slot to make them
redundant.